SENSOR
Technology for Human life
SENSOR
Technology for Human life
Electrochemical
0 - 500 ppm CO / 0 - 200 ppm H2S
Applications
• Ideal for multigas portable instrument
• Industry safety (ambient air monitoring appllications)
• Residential CO alarms
• Sewers, Wastewater treatment, Mining
• Etc.
Performance Characteristics |
|
---|---|
Output Signal | 80±20 nA/ppm CO / 775±275 nA/ppm H2S |
Typical Baseline Range (pure air) |
≤±2 ppm CO / ≤±0.5 ppm H2S equivalent |
T90 Response Time |
<30 seconds |
Measurement Range |
0-500 ppm CO / 0~200 ppm H2S |
Maximum Overload |
2,000 ppm CO / 500 ppm H2S |
Linearity |
Linear |
Repeatability |
≤±3% CO / ≤±2% H2S equivalent |
Recommended Load Resistor |
10 ohms |
Resolution (Electronics Dependent) |
≤0.5 ppm typical |
Environmental | |
Temperature Range Continuous |
-20℃ to +50℃ |
Pressure Range |
800 to 1200 mbar |
Operating Humidity Range |
15% to 90% Rh |
Life Time |
|
Long Term Output Drift |
≤5% per annum |
Recommended Storage Temp. |
0℃ to 20℃ |
Expected Operating Life |
≥24 months in air |
Standard Warranty |
24 months from the date of dispatch |
Intrinsic Safety Data |
|
Maximum at 2,000ppm |
30mA |
Maximum o/c Voltage |
<1.3V |
Maximum s/c Current |
<1.0A |