SENSOR

Technology for Human life

Gas Sensor
Home > SENSOR > Gas Sensor
senson_icon.jpg

High Quality Electrochemical Gas Sensor

Sensor technology is the basis of all Senko products. We are constantly investing in R&D to develop our own products that can not be imitated by developing our own technology.

Now, it is not competitive to make a product with the developed sensor. We will develop new products that will win in the market by developing everything from sensor to product according to the requirements of the market.

Hydrogen chloride (HCl)

Electrochemical
0 - 20 ppm

Model #SS2188 (HCl) 요약정보

Applications

• Portable and fixed gas detectors

• Leakage and TLV-monitoring

• Semiconductor industry

• Fast response and stable baseline

현재 상품 상세설명

Specification

 

Performance Characteristics

Output Signal 200±50 nA / ppm

Typical Baseline Range (pure air, @ 20℃)

≤ ±0.5 ppm HCl equivalent

Baseline Shift (-20℃ ~ 50℃)

≤ ±2 ppm typical

Response Time (T90)

< 50 seconds

Filter

None

Measurement Range

0-20 ppm

Maximum Overload

40 ppm

Linearity

Linear

Repeatability

≤ ±2% of signal

Recommended Load Resistor

10 ohms

Resolution (Electronics Dependent)

< 0.5 ppm typical

Bias Volage

0 mV

Environmental

Temperature Range Continuous

-20℃ to +50℃

Pressure Range

800 to 1200 mbar

Operating Humidity Range

15% to 90% RH

Lifetime

Long Term Output Drift

< 5% per annum

Recommended Storage Temp.

0℃ to 20℃

Expected Operating Life

> 24 months in air

Standard Warranty

24 months from the date of dispatch

Intrinsic Safety Data

Maximum at 40ppm

10 μA

Maximum o/c Voltage

< 1.0V

Maximum s/c Current

< 0.1A

 

 

Temperature Effect

Sensitivity

Standard Operation Circuit